Radiometric Phase Calibration


ALMA Water Vapor Radiometry Interest Group

Phase Stability

Inhomogeneously distributed water vapor results in different electrical path lengths above the different antennas, or phase error. The phase errors scatter flux, limiting the dynamic range, and also cause decorrelation, which artificially decreases the source amplitude.
Effects of phase errors on imaging has been studied for the MMA, and the intrinsic phase stability of the sites is being measured.

Since the intrinsic phase stability of even the best sites is often not sufficient for long baseline (>1000m) or high frequency (>200 GHz) observations, we are actively investigating several ways of correcting for the phase errors. The MDC Phase Stability Working Group Report outlines several strategies for calibrating the phase on very short timescales. The leading methods are fast switching phase calibration, traditional phase calibration performed on ~10 second cycles, and radiometric phase correction, which determines the amount of water vapor above each antenna radiometrically and calculates the phase by dead reckoning. Preliminary work suggests that either of these methods will permit 220 GHz observations on long baselines most of the time on the Mauna Kea or Chilean sites, but there are many details yet to be sorted out.

We expect much progress in this area as radiometric phase correction instrumentation becomes operational at each of the existing millimeter interferometers. Some of the ongoing radiometric calibration projects include:

MMA Memo #271: The Determination of Precipitable Water Vapour at Llano de Chajnantor from Observations of the 183 GHz Water Line

WVR Meeting Notes - 07 June 1999 in Tucson

Phase Corrections at the OVRO Millimeter Aray using Atmospheric Water Vapor Observations

Caltech 22 GHz Water Line Monitor (WLM)

MMA Memo 209: 183 GHz Radiometric Phase Correction for the MMA by O. Lay

183 GHz radiometer for CSO-JCMT Interferometer (M. Wiedner's thesis). More recent results from October 1998 are found here.

LSA 183 GHz Site Testing Radiometer (ESO)

LSA 183 GHz Site Testing Radiometer (OSO)




Last modified: January 19, 2000