Return to Memolist

MMA Memo 128: Sensitivity of the MMA in Wide Field Imaging

M.A. Holdaway (mholdawa@nrao.edu)
M.P. Rupen (mrupen@nrao.edu)
National Radio Astronomy Observatory
Socorro, NM 87801

June 16, 1995

Abstract

The MMA D array used in mosaicing mode will provide a very sensitive and efficient means of imaging very large fields. With integration times per pointing of only 1 s, the MMA D array can achieve surface brightness sensitivity at 115 GHz and 1.3 km/s spectral resolution of 0.19 K at the full resolution and 0.076 K when tapered to resolution ( is similar to the resolution obtained with a 50 m single dish at 115 GHz). Observing 1 s per pointing at 230 GHz with 1.3 km/s spectral resolution, sensitivities of 0.25 K at the full resolution and 0.10 K when tapered to resolution can be achieved. With these interesting sensitivity levels in only 1 s per pointing, mosaics of thousands of pointings will be desirable. Utilization of this powerful capability of the MMA will require continuous scan (On-The-Fly) mosaicing, smooth synchronous tracking by all antennas to a few arcseconds pointing accuracy, and correlator dump times of 0.3 s or less.

It can be argued that large single dishes equipped with large focal plane arrays should be more capable at imaging such large regions of the sky. When compared at the same resolution, the MMA is several times faster at wide field imaging than a ``straw man'' large single dish. Much more computer time will be required to process the MMA data than the single dish data, but the MMA images are likely to be of higher quality.

Introduction

Traditionally, single dish radio telescopes have been used to image diffuse objects such as atomic or molecular clouds in our Galaxy, and radio interferometers have been used to image extragalactic objects, discrete galactic objects, or compact features embedded in the diffuse galactic objects. While it has been widely recognized that multiple interferometric pointings may be required to image objects of modest size (Rand and Kulkarni, 1990; Adler et al., 1992), the prejudice for observing very large objects with single dishes is still widespread in the radio astronomical community. The design of the MMA attempts to remove this traditional distinction between ``single dish science'' and ``interferometer science'' since the MMA D array measures all spatial frequencies from zero up to the longest baseline, thereby permitting observations of arbitrarily large sources (Cornwell 1988, Cornwell, Holdaway, and Uson 1993). In this memo, we look at the sensitivity of the MMA D array to illustrate that very large (i.e., thousands of pointings) mosaic observations are both feasible and interesting, and we also demonstrate that the MMA images wide fields faster than a straw man large single dish with a focal plane array.

Mosaicing Brightness Sensitivity and Implied Mosaic Size

The surface brightness sensitivity of a single pointing interferometric observation will be

where f is the filling factor of the array, or the fraction of the array area which is filled with antenna collecting area, is the aperture efficiency of a single element, is the number of polarizations, is the observing time, and is the bandwidth. For mosaicing, the brightness sensitivity is further improved by the overlap in pointings, which is given by

where is the primary beam, and is the pointing position. For a regular square grid of Nyquist sampled interferometer pointings, is constant (except at the edge of the sky coverage) and equal to 1.60. Oversampling by a factor of two in each direction would increase by a factor of about 2, but the amount of time per pointing would decrease by 4, resulting in the same sensitivity. Hence, the mosaicing sensitivity specific to our rectangular Nyquist sampled grid applies to the general case. So, for rectangular grid mosaic observations, the surface brightness sensitivity is

with now being the time per pointing. For CO(1-0) at 115 GHz, imaged with the D array at full resolution (), with , f for the D array is 0.5, = 1.60, , =2, = 1 s, and = 0.5 MHz, or 1.3 km/s, resulting in 0.19 K surface brightness sensitivity. However, if we taper the image to half the resolution, the beam is 4 times as large and we lose only of the point source sensitivity, resulting in an improvement in surface brightness sensitivity of , or K. For CO(2-1) at 230 GHz, , full spatial resolution ( spatial resolution and 1.3 km/s spectral resolution), K; and at half spatial resolution () K.

Past surveys of galactic CO (see e.g. Combes, 1991) have had sensitivities ranging from 0.5 K down to 0.1 K, typically either with telescope beams of (which allows observation of only a very small fraction of a percent of the sky), or with telescope beams of about (which permits surveying a substantial fraction of the sky with a dedicated instrument). The sensitivity of the MMA in only one second per pointing is comparable to that of the most sensitive of these surveys, but at resolutions of . This gives us the possibilities of imaging very large regions of the sky at K sensitivities (about 0.5% of the sky in 1 month of dedicated observing, far exceeding the paltry fractions of the sky which have been observed in CO at resolution in past surveys, typically 0.01% of the sky), and of spending more time per pointing to perform more sensitive surveys of weaker molecular transitions, such as CO.

We can conclude from the sensitivity arguments and comparisons with the sensitivities of past CO surveys that mosaicing with as little as 1 s per interferometric pointing is actually a very interesting way to spend MMA time because it probes new phase space (namely higher spatial resolution) in a time efficient manner. At 1 s per pointing, 3000 pointings can be made in an hour, resulting in mosaics of 600 x 600 pixels (full resolution at 115 GHz), about a quarter square degree per hour.

Sensitivity Comparison Between the MMA and a Large Single Dish

It might seem that a large single dish with a multi-feed array would be a more practical means of mapping such large regions of the sky; in fact, the MMA will be very fast at wide field imaging. To demonstrate the MMA's speed, we compare the imaging speed of the proposed MMA with a ``straw man'' 50 m single dish with a 32 beam focal plane array. This is an interesting comparison because the two instruments have the same collecting area, and the 32 beam focal plane array is the largest focal plane array currently planned. To calculate the relative sensitivity of these two instruments, we first consider the number of pointings each instrument must make to cover the same large piece of sky, and we then ask what the sensitivity is on the sky given a certain amount of time observing that position. We can then determine the relative speeds of the two instruments.

Since the large single dish will be tapered, one single dish beam width will be about m. The MMA dishes will not be tapered (see below), and the primary beam width will be closer to m. So, the ratio of the number of large single dish primary beams to MMA primary beams in some large region will be

However, the large single dish will have 32 feeds, so the ratio of the number of antenna pointings required by the large single dish and the MMA to image the same region will be

Next, we consider how sensitive the two instruments are at a single sky position in a given amount of time. The sensitivity in Jy of a single dish is given by the equation

where is the antenna efficiency, is the collecting area of the dish, and is the number of polarizations measured. We break up into the surface efficiency , the taper efficiency , the switching efficiency , and other efficiencies including spill over and blockage. The sensitivity in Jy of an N element interferometer is given by the equation

is the collecting area of one MMA dish, N is the number of antennas in the array. The difference of in the sensitivity equations is due to the requirement that the total power receivers must be switched against a reference load, which is not required of the interferometer's receivers. For a mosaicing interferometer, we break up the efficiency into the surface efficiency , the taper efficiency , and other efficiencies including spill over and blockage. In addition, we must consider the mosaicing sensitivity overlap .

These factors are summarized in Table 1 for the 50 m SD and the MMA.

 
Table: Factors influencing the single pointing sensitivity of the Large Single Dish and the MMA tapered to the same resolution.

The ratio of the sensitivity equations gives us

For the parameter values in Table 1,

In order to compare the relative speed of the large single dish and the MMA ( ie, the relative time required to image the same region of the sky to the same sensitivity), we multiply the relative sensitivity on each pointing, squared, by the relative number of antenna pointings required to image some large region of the sky:

or

Hence, it appears that the MMA will be significantly more efficient at imaging very large regions than a large single dish. We can turn the equation backwards and ask: given a single dish with the same collecting area as the MMA, how many feeds must it have to be as fast as the MMA in wide field mapping? It must have 8.5 times more feeds than its assumed 32, or about 270 feeds total to keep up with the MMA. With current technology, an array of 270 feeds on a millimeter wavelength telescope would suffer from severe off-axis effects, resulting in the different feeds having quite different beams.

It is a bit precarious to compare the sensitivities of two instruments which have not yet been built. In addition to uncertainties in the above factors, we have not considered these additional factors:

Technical Requirements for the MMA

If the antennas observe in ``stop and go'' mode, as mosaicing is performed currently, something like 5 s will be lost to the antenna settling down to the good pointing accuracy required for mosaicing, and very large mosaicing becomes less attractive. In order to make full use of the power of the MMA, continuous scan (i.e., On-The-Fly) mosaicing (Holdaway and Foster 1994) will be required. In order for On-The-Fly mosaicing to work, the antennas must scan synchronously. However, since these mosaics will not be very high dynamic range, of order 50:1 or 100:1, the 1 arcsecond pointing is not required, rather, we could probably live with 2-3 arcsecond pointing. Jim Ruff, a VLA antenna engineer, says that the synchronous scanning requirement is not particularly hard to meet, but must be included in the design specifications. With 1 s integration times per Nyquist sampled pointing position, the correlator readout needs to be about 0.3 s. An outstanding problem is the shape of the synthesized beam, which will change across the image unless one of the solutions of Holdaway and Foster (1994) is adopted: flagging data which fall outside the envelope common to all pointings, restricting the observations to a small hour angle range (thereby limiting the size of the mosaics made on any given day), or scanning over the imaged region very fast several times, which requires a very small correlator dump time. Discussion of which scheme is most appropriate is outside the scope of this memo. Flagging the non-overlapping points will degrade the resolution (but will enhance the surface brightness sensitivity). Scanning over the region many times will create extreme data rate problems and may not be technically feasible within the constraints of the MMA budget.

Conclusions

With only 1 s integration per pointing, the MMA D array gives very respectable surface brightness sensitivity, comparable to the best existing surveys at much lower resolution. In order to take advantage of this sensitivity and the associated capability of imaging very large regions of the sky, the MMA correlator must have a fast dump time and the antennas must be able to point well while scanning. Lots of computation will be required to produce these large images, much more than will be required for a large single dish. The MMA will image wide fields considerably faster than a large single dish with the same collecting area and a reasonable number of feeds; in fact, the single dish's focal plane array will require 270 feeds in order to image as quickly as the MMA. Hence, any scientific justification for a large millimeter wavelength single dish to image large regions of the sky applies equally well to the MMA. If the technical challenges of fast correlator dump times and synchronous slewing can be met at modest cost, it would probably be very fruitful scientifically to add the fast mosaicing capabilities to the MMA.

References

Adler, et al., 1992, ``A Completely Sampled Aperture Synthesis Map of the CO Emission in M51'', ApJ 392, 497.

Combes, Francoise 1991, ``Distribution of CO in the Milky Way'', in Annu. Rev. Astron, Astrophys., 29:195-237.

Cornwell, 1988, ``Radio-interferometric imaging of very large objects'', A&A 143, 77.

Cornwell, Holdaway, and Uson, 1993, ``Radio-interferometric imaging of very large objects: implications for array design'', A&A 271, 697-713.

Holdaway, M.A., and Foster, Scott, 1994, ``On-The-Fly Mosaicing'', MMA Memo 122.

Rand and Kulkarni, 1990, ApJ, 349, (L43).

Many thanks to Darrel Emerson, Frazer Owen, Harvey Liszt, Claire Chandler, Jim Ruff, and Phil Jewell for their useful inputs into this work.